Is the door free from missing or broken parts.
Annual fire door inspection form.
Is the door undercut no more than inch.
Nfpa 80 requires both sides of swinging fire doors to be inspected and tested according to the following 13 items.
Fill out securely sign print or email your annual inspection of swinging fire door assemblies healthandwelfare idaho instantly with signnow.
Start a free trial now to save yourself time and money.
The egress door inspection and testing requirements do not apply to every door in a.
Fire door inspections annual fire door inspections were introduced with the adoption of the 2007 edition of nfpa 80.
Available for pc ios and android.
The 2012 edition of the life safety code nfpa 101 requires facilities to complete annual fire and smoke door inspection and testing.
The newest standard requires that fire rated doors be tested for functionality no less than annually and that a written record of the inspection be kept on file for the authority having jurisdiction ahj.
Is the clearance from the door edge to the frame no more than 1 8 inch.
Full compliance with the annual fire door assembly inspection and testing in accordance with 2010 nfpa 80 is required by january 1 2018.
Life safety code lsc deficiencies associated with the annual inspection and testing of fire doors should be cited under k211 means of egress general.
13 points points doors inspection.
Does the active door leaf completely close when.
Section 18 2 2 2 1 19 2 2 2 1 requires compliance with section 7 2 1 and section 7 2 1 15 2 requires compliance with nfpa 80 standard.
It is recommended that a facility identify all doors to be inspected on drawing layout of the facility to track inspections.
Cms annual inspection per nfpa 101.
Annual fire door inspection form.
Fire door field labeling and certification as defined in nfpa 252 or ul 10b c.
Fire damper commissioning fire smoke door inspection maintenance fire and smoke door repair and installation fire door labeling firestop survey installation above ceiling firestop survey fire barrier survey statement of conditions.
Manual fire alarm boxes ion detectors photo detectors duct detectors heat detectors waterflow switches supervisory switches other specify.
The most secure digital platform to get legally binding electronically signed documents in just a few seconds.
Annual inspection of fire and egress doors.
Are the doors hinges frame hardware and threshold secure aligned and in working order with no visible signs of damage.
Complete one form for each door inspected.